How to Replace an AO Smith Water Heater Thermostat

Are you looking to replace the water heater thermostat on your AO Smith water heater? If so, you’ve come to the right place. AO Smith is an Original Equipment Manufacturer. These thermostats include everything you need to replace the thermostat and the cover on a two-element heater. Keep reading to learn how to replace your thermostat. Once you replace the thermostat, you’ll have to purchase a new water heater to ensure its long-lasting performance.

AO Smith water heater reset button

The A.O. Smith water heater thermostat reset button is located under a metal cover. This button is usually covered in insulation or Styrofoam. You can find it by unscrewing the cover with a screwdriver. Once you have found the button, follow these steps to reset the thermostat on your water heater. This procedure may take several minutes. Ensure that you follow the instructions carefully and you should be able to successfully reset your water heater.

If you find the button tripped again, you can try resetting your water heater. However, you should be careful because this could result in serious trouble and risk to your heater. The tripped button may be a sign of major problems with your water heater. To be on the safe side, contact AO Smith water heater technical support to find out if this is an issue with your water heater. If you do not know where to locate it, refer to the manufacturer’s manual for further instructions.

AO Smith water heater thermal switch

How to Replace an AO Smith Water Heater Thermostat

When you suspect that the AO Smith water heater thermostat thermal switch is malfunctioning, there are a few things you should do to reset it. First, power off the unit and then back on. Press and hold the buttons for 10 seconds. Then, release the buttons. You should hear a clicking sound. If it doesn’t, then you must replace the thermostat. After the switch is reset, turn on the water heater and check the temperature again.

The easiest way to reset your AO Smith water heater thermostat is to press the red reset button. The button is usually located on the electrical panel, behind the insulation. Press and hold the red reset button until it clicks. Then, wait for a few seconds for it to reset. If the unit still fails to heat water, you can try to reset it again. Otherwise, you may have to replace the entire unit.

AO Smith water heater thermal switch reset

In order to correct an AO Smith water heater thermostat malfunction, you must first reset the entire unit. To do this, open the electrical panel, remove the insulation, and push the red reset button. Wait for the switch to click. Then, reinstall the thermostat and check the unit for proper functioning. In case the reset button doesn’t work, contact AO Smith water heater technical support for further instructions.

If you’re experiencing trouble with an AO Smith water heater, you can simply reset the device by pressing the red reset button located behind the electric panel. Then, hold it down until it clicks. The water heater will now be back in working order. To check if your water heater is in the repair mode, you may need to remove the insulation and disconnect the unit from the electricity. After removing the insulation, press the red reset button once more until the unit’s reset button clicks.

AO Smith water heater reset button sound

If you have an AO Smith water heater, and you’ve noticed that the reset button isn’t working, you may need to reset it. You can do this by removing the insulation or the electric panel. Then, simply press the red reset button and hold it down until it clicks. Once it does, the unit will be reset. Once the water heater is reset, it should work again. Follow the steps below to reset your AO Smith water heater.

The gas valve on your water heater is a passive safety feature. When a water heater’s gas valve is shutting down or the reset button stops working, you may need to manually turn it back on to restart it. Then, you can connect the water heater to an outlet. If you are using a gas water heater, you may also need to reset the gas valve. The gas valve controls the amount of gas that is administered to light the ignitor and pilot. If the reset button sounds like an explosion, this is a common cause for a malfunction.

Water Heater Thermostat Wiring Diagrams

Water heater thermostat wiring diagrams vary between single element and multiple element water heaters. The upper thermostat L1 screw connects to the phase line from the main 120V/240V electrical panel. The second terminal of the thermostat (T2) is connected to the heating element. The earth or ground (G) is connected to the junction box of the water heater. Once these two wires are connected, the thermostat is ready for operation. Here’s how the wiring diagrams for each element look.

To troubleshoot a faulty water heater thermostat, first find the water heater element. It’s screwed into the water heater tank and has two wire terminals. When the thermostat closes its contacts, voltage travels through the element and creates heat. Most elements fail in this area. A faulty wire terminal is black and loosely connected. To troubleshoot this element, you’ll need a meter to determine the voltage.

The upper thermostat is operated by a bimetallic strip attached to its terminals. Terminal no. 1 is connected to the upper element, while terminal no. 2 is connected to the lower element. If you don’t find any figures, the thermostat is not working properly. If the top thermostat is functioning properly, the other two should be checked to make sure they’re connected. You’ll need to perform a visual inspection to determine whether you’ve found a loose or carbon-filled wire.

The electric water heater is fed from the main electrical panel, but some models are fed from a separate fuse box. If your electric water heater’s circuit breaker trips without any apparent reason, you can try resetting the toggle. Flip the switch back to the “On” position to reset both legs of the circuit breaker. If this doesn’t solve the problem, you need to check the voltage level across both legs of the circuit breaker’s terminals. During this time, turn on the hot water tap and let the system heat up to its maximum setting.

AO Smith Electric Water Heater Troubleshooting

 

AO Smith Electric Water Heater Troubleshooting

If you have an AO Smith electric water heater, you may be wondering what to do if it stops working. This device provides hot water for your daily tasks and prevents pipes from freezing during the winter. Fortunately, there are a number of easy ways to troubleshoot your AO Smith water heater, whether it’s a new model or an old one. In this article, we’ll go over a few common problems and how you can fix them.

The most common AO Smith electric water heater problems stem from a clogged intake filter. In fact, the filter is actually a pre-filter. You can easily clean this filter with a long brush or 90-degree tubing and a shop vac. You can also use an old sponge or even a hairdryer to scrub it clean. AO Smith electric water heater troubleshooting focuses on the 100 series. If you are experiencing pilot light problems, the thermocouple may be faulty. The pilot assembly may need to be replaced.

The thermostat is a basic part of your A.O Smith water heater. It sends signals to the heating element to raise or lower the water temperature. If it’s malfunctioning, the reset button will trip. It’s often caused by an electrical problem, including faulty wiring or a blown circuit breaker. In some cases, the problem may be easily remedied by replacing the heating element.